Depo logosu MEF | GCRIS Araştırma Bilgi Yönetim Sistemi
English
Türkçe
Русский
Yeni kullanıcı mısınız? Kayıt olmak için buraya tıklayın.Parolanızı unuttunuz mu?
Ana Sayfa
Araştırma Kataloğu
Genel Bakış
GCRIS Rehberi
Bölümler/Koleksiyonlar
GCRIS'i Keşfet
İstatistik
  1. Anasayfa
  2. 12. Akademik Birimler
  3. 03. Faculty of Arts Design and Architecture
  4. Konuya Göre Gözat

Konu "3d adaptive pushover" ile göz atma

Veya ilk birkaç harfi girin:
Şimdi gösteriliyor 1 - 1 / 1
  • Sayfa başına sonuç
  • Sıralama Seçenekleri
  • Yükleniyor...
    Makale
    Case Study on Seismic Behavior of Aseismically Designed Reinforced Concrete Frame Structures
    (Springer, 2017) Oyguc, Evrim; Oyguc, Resat; Tönük, Gökçe
    In this study, the seismic performances of two aseismically designed plan-irregular reinforced concrete frame (RCF) households damaged during the October 23, 2011 Van earthquake are assessed. Since no strong ground motion recordings from the main shock were available, first, strong ground motion parameters of the event are evaluated and then compatible with these parameters suits of real records are selected and scaled to match with the event's simulated acceleration spectrum to be used in the analytical investigations. The results of previous reconnaissance studies, in which one of the present authors was involved, are then discussed. Capacities of the considered RCF's are determined applying a 3D single-run adaptive pushover procedure that is capable of considering the effect of plan irregularities. The performance assessment procedure based on the current 2007 Turkish Earthquake Code is then applied to these investigated buildings. Additionally, nonlinear dynamic time history analyses are carried out using the previously selected time histories. The hysteretic behavior of the considered buildings is examined as the consequence of the conducted analyses and considering the different suits of selected ground motions, the seismic response of the buildings is evaluated in terms of interstorey drifts. None of the buildings are found to satisfy the expected performance level. Moreover, the numerical results are found to have good correlation with the field observation results.
Depo logosu
Koleksiyonlar
  • Scopus Koleksiyonu
  • WoS Koleksiyonu
  • TrDizin Koleksiyonu
  • PubMed Koleksiyonu
  • Tez Koleksiyonu
Araştırma Kataloğu
  • Araştırma Çıktıları
  • Organizasyonlar
  • Araştırmacılar
  • Projeler
  • Ödüller
  • Ekipmanlar
  • Etkinlikler
Hakkında
  • İletişim
  • GCRIS
  • Research Ecosystems
  • Görüş ve Öneri
  • OAI-PMH

GCRIS Dashboard'a Giriş Yapın

GCRIS Mobile

App Store'da GCRIS Mobile İndirGoogle Play'de GCRIS Mobile Edin

Research Ecosystems tarafından yapılmıştır