Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11779/1952
Title: | State of the Art in Application of Seismic Isolation and Energy Dissipation in Turkey | Authors: | Şadan, Bahadır | Keywords: | Earthquake Isolation Performance Turkey Buildings Seismic Bridges |
Publisher: | Springer International Publishing Ag | Source: | Sadan, B. (2023). State of the Art in Application of Seismic Isolation and Energy Dissipation in Turkey. In World Conference on Seismic Isolation (pp. 17-25). Cham: Springer International Publishing. | Abstract: | This paper summarizes the passive structural control system applications and other related developments in Turkey, emphasizing the period between 2019 and 2022. The country hosts state-of-the-art seismic isolation applications, relatively greater in size, and use more isolators in each project (415 isolators per building on average) compared to the other seismic isolation projects worldwide. Construction of the world's largest seismic isolated building, Istanbul Basaksehir Pine and Sakura City Hospital, covering more than 1 million square meters of area and employing more than 2000 seismic isolators, was completed and has been in service since May 2020. 1915 Canakkale Bridge, constructed in memory of the great war of Canakkale during World War I, is now the world's longest suspension bridge with a 2023m main span length. Eight massive hydraulic dampers were used at the main deck and 48 at the approach viaducts in combination with 72 seismic isolators. Construction of a residential building complex in Istanbul consisting of 16 isolated blocks covering more than 170,000 m(2) area and having 454 seismic isolators is coming to an end very soon. Historical Nusretiye Clock Tower in Istanbul was relocated a few meters over seismic isolators. Historical Goztepe Railway Station in Istanbul was retrofitted to accommodate an additional railway line using seismic isolation technology. Seismic codes for buildings and bridges now include rules for the seismically isolated design of structures. Additionally, all seismic isolation designs must be peer-reviewed by law. A new seismic isolator testing facility was established in Eskisehir to respond to the demand for the large number of isolators that need to be tested. | URI: | https://hdl.handle.net/20.500.11779/1952 https://doi.org/10.1007/978-3-031-21187-4_2 |
ISBN: | 9783031211898 9783031211874 9783031211867 |
ISSN: | 2366-2557 2366-2565 |
Appears in Collections: | İnşaat Mühendisliği Bölümü Koleksiyonu Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Show full item record
CORE Recommender
SCOPUSTM
Citations
3
checked on Nov 16, 2024
WEB OF SCIENCETM
Citations
3
checked on Nov 16, 2024
Page view(s)
34
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.