İnşaat Mühendisliği Bölümü Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.11779/1943
Browse
Browsing İnşaat Mühendisliği Bölümü Koleksiyonu by Subject "Behavior"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Article Citation - WoS: 9Citation - Scopus: 10Damage Accumulation Modelling of Two Reinforced Concrete Buildings Under Seismic Sequences(Springer, 2023) Tönük, Gökçe; Oyguç, Reşat; Oyguç, Evrim; Uçak, DorukThe extent of earthquake damage depends solely on the seismicity, site conditions and vulnerability of the building stock in a region. Hence, studies to assess the seismic behavior of building stocks with similar vulnerabilities are important to mitigate seismic risk in earthquake-prone regions. This study aims to simulate the seismic behavior of selected reinforced concrete (RC) school buildings by modelling damage accumulation under multiple earthquakes sequence. The observed data of two RC school buildings heavily damaged after the 2011 Van earthquake sequence in Turkey, namely, the Gedikbulak and Alakoy schools is used. Among these two school buildings, the Gedikbulak school building collapsed immediately after the main excitation, while the Alakoy school building withstood several seismic sequences, suffering heavy damages. In this study, three-dimensional numerical models that can consider the deterioration effects are developed and the capacities of the buildings were evaluated by conducting a force-based adaptive pushover procedure. Additionally, non-linear dynamic analyses were conducted using the concrete plastic damage model. Both degrading and conventional material models were used to examine the structural response under multiple ground motion sequences. The hysteretic behaviors of the studied buildings are presented. Consequently, analytical results are well correlated with the reconnaissance studies and neither of the considered structures are found to satisfy the design performance level.Article Citation - WoS: 9Citation - Scopus: 13Out-Of Seismic Performance of Bed-Joint Reinforced Autoclaved Aerated Concrete (aac) Infill Walls Damaged Under Cyclic In-Plane Displacement Reversals(Elsevier Sci Ltd, 2023) İlki, Alper; Demir, Uğur; Halıcı, Ömer Faruk; Zabbar, YassinThe infill walls made of Autoclaved Aerated Concrete (AAC), which is a lightweight, fire resistant and energy efficient material, provide effective insulation solutions for building types of structures and becoming more and more popular in earthquake prone regions. Although the number of experimental tests examining the seismic response of clay brick infills is extensive, the amount of prior research on infill walls built of AAC blocks is rather limited. Past research revealed that the use of bed-joint reinforcement is one of the promising solutions to improve the global seismic response of masonry walls by enhancing strength and displacement capacity. In this study, the out-of-plane (OOP) seismic performance of AAC infill walls with flat-truss and innovative cord-type bed-joint reinforcement is experimentally evaluated. Also, consideration is given to the prior in-plane (IP) damage, which was found to degrade the seismic performance of infills in OOP direction. For this purpose, three IP and four OOP, in total, seven experimental tests were performed on four full-scale AAC infill wall specimens. The test parameters were selected in such a way as to make it possible to parametrically compare the OOP performance of AAC infills with flat-truss and cord-type bed-joint reinforcements with unreinforced AAC infill walls, together with the effect of prior IP damage on the OOP response of unreinforced AAC infill walls. It was found that the use of innovative cord-type bed-joint reinforcement improved the OOP strength to a similar extent to what was obtained from the truss-type reinforced specimen. In terms of ultimate displacement and energy dissipation capacity enhancement, the specimen with cord-type reinforcement performed better. In addition, the damages formed due to IP cyclic displacement reversals up to 0.005 drift ratio, which is defined as the drift limit for buildings with brittle infill walls in certain design codes, resulted in a significant reduction in the OOP strength and stiffness properties of AAC infills. The theoretical OOP strength calculations were found to provide unconservative strength values for the IP-damaged specimens.