İnşaat Mühendisliği Bölümü Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.11779/1943
Browse
8 results
Search Results
Conference Object Citation - Scopus: 1Investigation Procedure for the Diagnosis of Historical Minarets: Inclined Minaret of Sivas Ulu Cami (mosque)(Springer, 2024) İnci, Pınar; Halıcı, Ömer Faruk; Aldırmaz B.; Çoban S.; Halıcı, Ömer Faruk; Cömert M.; Kiraz F.; Comert, M.; Aldirmaz, B.; Ilki, A.; Coban, S.; 02.04. Department of Civil Engineering; 02. Faculty of Engineering; 01. MEF UniversityThe inclined minaret of Sivas Ulu Cami (Mosque) from the 13th century Danishmend Period is one of the most invaluable architectural heritages in Turkey. The extent of inclination of the minaret towards the North-West direction, the seismicity of the region, and structural damages that occurred in time have emphasized the need for comprehensive structural and geotechnical investigations. Accordingly, a rehabilitation project is currently going on under the coordination of the General Directorate of Foundations of Turkey. Within the scope of the project, first, a series of field surveys have been conducted to obtain the current features of the minaret including the characteristics of the structural system, damages, deviation from the vertical axis, ground conditions and foundation details. In addition to that, a monitoring system including inclinometers, linear potentiometers and accelerometers has been mounted for tracking the evolution of deformations and damages in time under environmental influences and extracting the dynamic properties of the minaret. Findings from the field survey and monitoring system were used for constructing an analytical model of the structural system of the minaret. Then nonlinear time history analyses were conducted under various strong ground motion records to estimate the seismic performance of the minaret when subjected to earthquakes of different characteristics. The results showed that the tensile stresses that occurred due to seismic actions exceeded the tensile strength of the brick masonry at the region of the transition segment and the cylindrical body (top level of the boot).Article Citation - WoS: 1Citation - Scopus: 2Probabilistic Seismic Microzonation for Ground Shaking Intensity, a Case Study in Türkiye(Springer, 2023) Tönük, Gökçe; Tönük, Gökçe; 02.04. Department of Civil Engineering; 02. Faculty of Engineering; 01. MEF UniversityThe purpose of seismic microzonation is to estimate earthquake characteristics on the ground surface based on a probabilistic approach to mitigate earthquake damage in the foreseeable future for the new buildings, as well as for the existing building stock. The probabilistic analysis and related results are very important from an engineering perspective since the nature of the problem can only be dealt with in a probabilistic manner. The uncertainties associated with these analyses may be large due to the uncertainties in source characteristics, soil profile, soil properties, and building inventory. At this stage, the probability distribution of the related earthquake parameters on the ground surface may be determined based on hazard-compatible input acceleration-time histories, site profiles, and dynamic soil properties. One option, the variability in earthquake source and path effects may be considered using a large number of acceleration records compatible with the site-dependent earthquake hazard. Likewise, large numbers of soil profiles may be used to account for the site-condition variability. The seismic microzonation methodology is proposed based on the probabilistic assessment of these factors involved in site response analysis. The second important issue in seismic microzonation procedure is the selection of microzonation parameters. The purpose being mitigation of structural damage, it is possible to adopt earthquake parameters like cumulative average velocity (CAV) or Housner intensity (HI) that was observed to have better correlation with building damage after earthquakes. A seismic microzonation procedure will be developed with respect to ground shaking intensity considering probabilistic values of the cumulative average velocity (CAV) or Housner intensity (HI).Article Citation - WoS: 12Citation - Scopus: 13Damage Accumulation Modelling of Two Reinforced Concrete Buildings Under Seismic Sequences(Springer, 2023) Tönük, Gökçe; Tönük, Gökçe; Oyguç, Evrim; Uçak, Doruk; 02.04. Department of Civil Engineering; 02. Faculty of Engineering; 01. MEF UniversityThe extent of earthquake damage depends solely on the seismicity, site conditions and vulnerability of the building stock in a region. Hence, studies to assess the seismic behavior of building stocks with similar vulnerabilities are important to mitigate seismic risk in earthquake-prone regions. This study aims to simulate the seismic behavior of selected reinforced concrete (RC) school buildings by modelling damage accumulation under multiple earthquakes sequence. The observed data of two RC school buildings heavily damaged after the 2011 Van earthquake sequence in Turkey, namely, the Gedikbulak and Alakoy schools is used. Among these two school buildings, the Gedikbulak school building collapsed immediately after the main excitation, while the Alakoy school building withstood several seismic sequences, suffering heavy damages. In this study, three-dimensional numerical models that can consider the deterioration effects are developed and the capacities of the buildings were evaluated by conducting a force-based adaptive pushover procedure. Additionally, non-linear dynamic analyses were conducted using the concrete plastic damage model. Both degrading and conventional material models were used to examine the structural response under multiple ground motion sequences. The hysteretic behaviors of the studied buildings are presented. Consequently, analytical results are well correlated with the reconnaissance studies and neither of the considered structures are found to satisfy the design performance level.Book Part Citation - Scopus: 24The Modified Post-Earthquake Damage Assessment Methodology for Tcip (tcip-Dam(Springer, 2021) Cömert, Mustafa; Halıcı, Ömer Faruk; Halıcı, Ömer Faruk; Demir, Cem; 02.04. Department of Civil Engineering; 02. Faculty of Engineering; 01. MEF UniversityPost-Earthquake damage assessment has always been one of the major challenges that both engineers and authorities face after disastrous earthquakes all around the world. Considering the number of buildings in need of inspection and the insufficient number of qualified inspectors, the availability of a thorough, quantitative and rapidly applicable damage assessment methodology is vitally important after such events. At the beginning of the new millennia, an assessment system satisfying these needs was developed for the Turkish Catastrophe Insurance Pool (TCIP, known as DASK in Turkey) to evaluate the damages in reinforced concrete (RC) and masonry structures. Since its enforcement, this assessment method has been successfully used after several earthquakes that took place in Turkey, such as 2011 Van Earthquake, 2011 Kutahya Earthquake, 2019 Istanbul Earthquake and 2020 Elazig Earthquake to decide the future of damaged structures to be either ‘repaired’ or ‘demolished’.Conference Object Citation - WoS: 10Citation - Scopus: 12Implications of Site Specific Response Analysis(Springer, 2018) Tönük, Gökçe; Tönük, Gökçe; Ansal, Atilla; 02.04. Department of Civil Engineering; 02. Faculty of Engineering; 01. MEF UniversityDefinition of design earthquake characteristics, more specifically uniform hazard acceleration response spectrum, on the ground surface is the primary component for performance based design of structures and assessment of seismic vulnerabilities in urban environments. The adopted approach for this purpose requires a probabilistic local seismic hazard assessment, definition of representative site profiles down to the engineering bedrock, and 1D or 2D quivalent or nonlinear, total or effective stress site response analyses depending on the complexity and importance of the structures to be built. Thus, a site-specific response analysis starts with the probabilistic estimation of regional seismicity and earthquake source characteristics, soil stratification, engineering properties of encountered soil layers in the soil profile. The local seismic hazard analysis would yield probabilistic uniform hazard acceleration response spectrum on the bedrock outcrop. Thus, site specific response analyses also need to produce a probabilistic uniform hazard acceleration response spectrum on the ground surface. A general review will be presented based on the previous studies conducted by the author and his co-workers in comparison to major observations and methodologies to demonstrate the implications of site-specific response analysis.Conference Object Citation - WoS: 1Citation - Scopus: 1A Simplified Approach for Site-Specific Design Spectrum(Springer, 2017) Tönük, Gökçe; Tönük, Gökçe; Ansal, Atilla; 02.04. Department of Civil Engineering; 02. Faculty of Engineering; 01. MEF UniversityThe design acceleration spectrum requires site investigations and site-response analyses in accordance with the local seismic hazard. The variability in earthquake source and path effects may be considered using a large number of acceleration records compatible with the earthquake hazard. An important step is the selection and scaling of input acceleration records. Likewise, a large number of soil profiles need to be considered to account for the variability of site conditions. One option is to use Monte Carlo simulations with respect to layer thickness and shear wave velocity profiles to account for the variability of the site factors. The local seismic hazard analysis yields a uniform hazard acceleration spectrum on the bedrock outcrop. Site-specific response analyses also need to produce a uniform hazard acceleration spectrum on the ground surface. A simplified approach is proposed to define acceleration design spectrum on the ground surface that may be considered a uniform hazard spectrum.Conference Object Observations From Geotechnical Arrays in Istanbul(Springer, 2015) Tönük, Gökçe; Tönük, Gökçe; Cetiner, Barbaros; Ansal, Atilla; Çtiner, Barbaros; 02.04. Department of Civil Engineering; 02. Faculty of Engineering; 01. MEF UniversityFew small earthquakes with local magnitude slightly larger than M-L = 4 were recorded by geotechnical downhole arrays that have been recently deployed in the west side of Istanbul. Same events were also recorded by Istanbul Rapid Response Network (IRRN) which comprises of 55 surface strong motion stations in the European side of Istanbul. The strongest one of these earthquakes took place on 12/3/2008 in Cinarcik with local magnitude of M-L = 4.8. Even though the observed PGAs were not exceeding 0.01 g, an effort is made to model the recorded response at the downhole array sites as well as the at the IRRN stations using the acceleration records obtained by the deepest sensors, i.e. on the engineering bedrock, at the downhole array sites as input bedrock motions. 1D equivalent linear site response analysis that is generally adopted for site-specific response analysis is used for modelling. Observations from the recorded response and results from 1D modelling of ground response have yielded in general good agreement between the observed and recorded soil response at the station sites.Article Citation - WoS: 6Citation - Scopus: 6Case Study on Seismic Behavior of Aseismically Designed Reinforced Concrete Frame Structures(Springer, 2017) Oyguc, Evrim; Tönük, Gökçe; Tönük, Gökçe; 02.04. Department of Civil Engineering; 02. Faculty of Engineering; 01. MEF UniversityIn this study, the seismic performances of two aseismically designed plan-irregular reinforced concrete frame (RCF) households damaged during the October 23, 2011 Van earthquake are assessed. Since no strong ground motion recordings from the main shock were available, first, strong ground motion parameters of the event are evaluated and then compatible with these parameters suits of real records are selected and scaled to match with the event's simulated acceleration spectrum to be used in the analytical investigations. The results of previous reconnaissance studies, in which one of the present authors was involved, are then discussed. Capacities of the considered RCF's are determined applying a 3D single-run adaptive pushover procedure that is capable of considering the effect of plan irregularities. The performance assessment procedure based on the current 2007 Turkish Earthquake Code is then applied to these investigated buildings. Additionally, nonlinear dynamic time history analyses are carried out using the previously selected time histories. The hysteretic behavior of the considered buildings is examined as the consequence of the conducted analyses and considering the different suits of selected ground motions, the seismic response of the buildings is evaluated in terms of interstorey drifts. None of the buildings are found to satisfy the expected performance level. Moreover, the numerical results are found to have good correlation with the field observation results.
