İnşaat Mühendisliği Bölümü Koleksiyonu

Permanent URI for this collectionhttps://hdl.handle.net/20.500.11779/1943

Browse

Search Results

Now showing 1 - 2 of 2
  • Conference Object
    Citation - WoS: 7
    Citation - Scopus: 5
    State of the Art in Application of Seismic Isolation and Energy Dissipation in Turkey
    (Springer International Publishing Ag, 2023) Şadan, Bahadır; Şadan, Bahadır; 02.04. Department of Civil Engineering; 02. Faculty of Engineering; 01. MEF University
    This paper summarizes the passive structural control system applications and other related developments in Turkey, emphasizing the period between 2019 and 2022. The country hosts state-of-the-art seismic isolation applications, relatively greater in size, and use more isolators in each project (415 isolators per building on average) compared to the other seismic isolation projects worldwide. Construction of the world's largest seismic isolated building, Istanbul Basaksehir Pine and Sakura City Hospital, covering more than 1 million square meters of area and employing more than 2000 seismic isolators, was completed and has been in service since May 2020. 1915 Canakkale Bridge, constructed in memory of the great war of Canakkale during World War I, is now the world's longest suspension bridge with a 2023m main span length. Eight massive hydraulic dampers were used at the main deck and 48 at the approach viaducts in combination with 72 seismic isolators. Construction of a residential building complex in Istanbul consisting of 16 isolated blocks covering more than 170,000 m(2) area and having 454 seismic isolators is coming to an end very soon. Historical Nusretiye Clock Tower in Istanbul was relocated a few meters over seismic isolators. Historical Goztepe Railway Station in Istanbul was retrofitted to accommodate an additional railway line using seismic isolation technology. Seismic codes for buildings and bridges now include rules for the seismically isolated design of structures. Additionally, all seismic isolation designs must be peer-reviewed by law. A new seismic isolator testing facility was established in Eskisehir to respond to the demand for the large number of isolators that need to be tested.
  • Conference Object
    Citation - WoS: 6
    Citation - Scopus: 11
    Near-Fault Earthquake Ground Motion and Seismic Isolation Design
    (Springer International Publishing Ag, 2023) Harmandar, Ebru; Şadan, Bahadır; Demircioglu-Tumsa, Mine B.; Şadan, Bahadır; Tuzun, Cuneyt; Ulker, Omer; 02.04. Department of Civil Engineering; 02. Faculty of Engineering; 01. MEF University
    Seismic isolation is one of the most reliable passive structural control techniques with adequately established standards for the earthquake protection of structures from earthquakes. However, it has been shown that the seismic isolation systems may not function the best for the near-fault ground motions, since in the proximity of a capable fault, the ground motions are significantly affected by the rupture mechanism and may generate high demands on the isolation system and the structure. In fact, several earthquake resistant design codes state that the seismically isolated structures located at near-fault sites should be designed by considering larger seismic demands than the demand on structures at far-field sites. When the fault ruptures in forward direction to the site most of the seismic energy arrives in coherent long-period ground velocity pulses. The ground-motion prediction equations (GMPEs) typically cannot account for such effects with limited distance metrics and lack adequate data at large magnitudes and near distances. For the reliable earthquake design of the isolated structure in near fault conditions that meets the performance objectives, the 3D design basis ground motion(s) need to be appropriately assessed. Measures in the design of the isolation system, such as modifications in the stiffness and damping characteristics, as well as in the limitation of vertical effects are needed. The behavior of the base-isolated buildings under near-fault (NF) ground motions with fling-step and forward-directivity characteristics are investigated with a rational assessment of design-basis near-fault ground motion, are investigated in a parametric format. The parametric study includes several variables, including the structural system flexibility; number of stories; isolation system characteristic (yield) strength, and the isolation periods related to the post-elastic stiffness. Furthermore, the effect of additional damping by viscous dampers were tested for some selected cases. Important findings observed from the parametric performance results and the overall conclusions of the study are provided.