The Effects of Ultrasound Parameters and Microbubble Concentration on Acoustic Particle Palpation

dc.contributor.author Körük, Hasan
dc.contributor.author Saharkhiz, Niloufar
dc.contributor.author Choi, James J
dc.date.accessioned 2018-09-18T06:37:43Z
dc.date.available 2018-09-18T06:37:43Z
dc.date.issued 2018
dc.description.abstract The elasticity of tissue—an indicator of disease progression—can be imaged by ultrasound elasticity imaging technologies. An acoustic particle palpation (APP) has recently been developed—the use of ultrasonically driven acoustic particles (e.g., microbubbles)—as an alternative method of tissue deformation. APP has the potential to improve the resolution, contrast, and depth of ultrasound elasticity imaging; but the tissue displacement dynamics and its dependence on acoustic pressure, center frequency, and microbubble concentration remains unknown. Here, displacements of at least 1 μm were produced by applying ultrasound onto a microbubble solution (concentration: 10 × 106 microbubbles ml–1) placed within a tunnel surrounded by a 5% gelatin phantom. Displacements of more than 10 μm were produced using a 1, 3.5, or 5 MHz center frequency pulse with peak-rarefactional pressures of 470, 785, and 1210 kPa, respectively. The deformation of the distal wall varied spatially and temporally according to the different parameters investigated. At low pressures, the deformation increased over several milliseconds until it was held at a nearly constant value. At high pressures, a large deformation occurred within a millisecond followed by a sharp decrease and long stabilization. Ultrasound exposure in the presence of microbubbles produced tissue deformation (p < 0.05) while without microbubbles, no deformation was observed.
dc.identifier.citation Saharkhiz, N., Koruk, H,. Choi, J.J. ( August 17, 2018 ) The Effects of Ultrasound Parameters and Microbubble Concentration on Acoustic Particle Palpation, The Journal of the Acoustical Society of America 144(2), pp.796-805. https://doi.org/10.1121/1.5050524
dc.identifier.doi 10.1121/1.5050524
dc.identifier.issn 0001-4966
dc.identifier.issn 1520-8524
dc.identifier.scopus 2-s2.0-85052332324
dc.identifier.uri https://hdl.handle.net/20.500.11779/211
dc.language.iso en
dc.publisher Acoustical Society of America
dc.relation.ispartof The Journal of the Acoustical Society of America
dc.rights info:eu-repo/semantics/openAccess
dc.title The Effects of Ultrasound Parameters and Microbubble Concentration on Acoustic Particle Palpation
dc.type Article
dspace.entity.type Publication
gdc.author.id Hasan Körük / 120879
gdc.author.id Hasan Körük / 0000-0003-4189-6678
gdc.author.institutional Körük, Hasan
gdc.bip.impulseclass C5
gdc.bip.influenceclass C5
gdc.bip.popularityclass C4
gdc.coar.access open access
gdc.coar.type text::journal::journal article
gdc.description.department Mühendislik Fakültesi, Makine Mühendisliği Bölümü
gdc.description.endpage 805
gdc.description.issue 2
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
gdc.description.scopusquality Q1
gdc.description.startpage 796
gdc.description.volume 144
gdc.description.woscitationindex Science Citation Index Expanded
gdc.description.wosquality Q1
gdc.identifier.openalex W2886631793
gdc.identifier.pmid 30180665
gdc.identifier.wos WOS:000443620700035
gdc.index.type WoS
gdc.index.type Scopus
gdc.index.type PubMed
gdc.oaire.accesstype HYBRID
gdc.oaire.diamondjournal false
gdc.oaire.impulse 4.0
gdc.oaire.influence 2.847913E-9
gdc.oaire.isgreen true
gdc.oaire.keywords 570
gdc.oaire.keywords MD Multidisciplinary
gdc.oaire.keywords 610
gdc.oaire.keywords Acoustics
gdc.oaire.popularity 4.257165E-9
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 0103 physical sciences
gdc.oaire.sciencefields 01 natural sciences
gdc.openalex.collaboration International
gdc.openalex.fwci 0.48558979
gdc.openalex.normalizedpercentile 0.61
gdc.opencitations.count 7
gdc.plumx.crossrefcites 6
gdc.plumx.mendeley 14
gdc.plumx.scopuscites 7
gdc.publishedmonth Ağustos
gdc.scopus.citedcount 7
gdc.virtual.author Körük, Hasan
gdc.wos.citedcount 6
gdc.wos.collaboration Uluslararası işbirliği ile yapılan - EVET
gdc.wos.documenttype Article
gdc.wos.indexdate 2018
gdc.wos.publishedmonth Ağustos
gdc.yokperiod YÖK - 2017-18
relation.isAuthorOfPublication 744d844c-212d-42fc-9d03-6d2657e550c3
relation.isAuthorOfPublication.latestForDiscovery 744d844c-212d-42fc-9d03-6d2657e550c3
relation.isOrgUnitOfPublication 00b4b5da-2140-4d4a-a2b0-9c4ae142ea53
relation.isOrgUnitOfPublication 0d54cd31-4133-46d5-b5cc-280b2c077ac3
relation.isOrgUnitOfPublication a6e60d5c-b0c7-474a-b49b-284dc710c078
relation.isOrgUnitOfPublication.latestForDiscovery 00b4b5da-2140-4d4a-a2b0-9c4ae142ea53

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Sharkhiz_Koruk_Choi2018.pdf
Size:
1.81 MB
Format:
Adobe Portable Document Format
Description:
Yazar Sürümü
No Thumbnail Available
Name:
The effects of ultrasound parameters and microbubble concentration on acoustic.pdf
Size:
3.33 MB
Format:
Adobe Portable Document Format
Description:
Yayıncı Sürümü

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.5 KB
Format:
Item-specific license agreed upon to submission
Description: