Near-Fault Earthquake Ground Motion and Seismic Isolation Design

dc.contributor.author Harmandar, Ebru
dc.contributor.author Erdik, Mustafa
dc.contributor.author Demircioglu-Tumsa, Mine B.
dc.contributor.author Şadan, Bahadır
dc.contributor.author Tuzun, Cuneyt
dc.contributor.author Ulker, Omer
dc.date.accessioned 2023-10-18T12:06:10Z
dc.date.available 2023-10-18T12:06:10Z
dc.date.issued 2023
dc.description.abstract Seismic isolation is one of the most reliable passive structural control techniques with adequately established standards for the earthquake protection of structures from earthquakes. However, it has been shown that the seismic isolation systems may not function the best for the near-fault ground motions, since in the proximity of a capable fault, the ground motions are significantly affected by the rupture mechanism and may generate high demands on the isolation system and the structure. In fact, several earthquake resistant design codes state that the seismically isolated structures located at near-fault sites should be designed by considering larger seismic demands than the demand on structures at far-field sites. When the fault ruptures in forward direction to the site most of the seismic energy arrives in coherent long-period ground velocity pulses. The ground-motion prediction equations (GMPEs) typically cannot account for such effects with limited distance metrics and lack adequate data at large magnitudes and near distances. For the reliable earthquake design of the isolated structure in near fault conditions that meets the performance objectives, the 3D design basis ground motion(s) need to be appropriately assessed. Measures in the design of the isolation system, such as modifications in the stiffness and damping characteristics, as well as in the limitation of vertical effects are needed. The behavior of the base-isolated buildings under near-fault (NF) ground motions with fling-step and forward-directivity characteristics are investigated with a rational assessment of design-basis near-fault ground motion, are investigated in a parametric format. The parametric study includes several variables, including the structural system flexibility; number of stories; isolation system characteristic (yield) strength, and the isolation periods related to the post-elastic stiffness. Furthermore, the effect of additional damping by viscous dampers were tested for some selected cases. Important findings observed from the parametric performance results and the overall conclusions of the study are provided.
dc.description.sponsorship Politecnico Torino
dc.identifier.citation Mustafa Erdik, Bahadır Şadan, Cüneyt Tüzün, Demircioglu-Tumsa, M. B., Ömer Ülker, & Ebru Harmandar. (2023). Near-Fault Earthquake Ground Motion and Seismic Isolation Design. Lecture Notes in Civil Engineering, 117–152. https://doi.org/10.1007/978-3-031-21187-4_9
dc.identifier.doi 10.1007/978-3-031-21187-4_9
dc.identifier.isbn 9783031211867
dc.identifier.isbn 9783031211874
dc.identifier.isbn 9783031211898
dc.identifier.issn 2366-2557
dc.identifier.issn 2366-2565
dc.identifier.scopus 2-s2.0-85148693217
dc.identifier.uri https://hdl.handle.net/20.500.11779/1951
dc.identifier.uri https://doi.org/10.1007/978-3-031-21187-4_9
dc.language.iso en
dc.publisher Springer International Publishing Ag
dc.rights info:eu-repo/semantics/closedAccess
dc.subject Forward-directivity
dc.subject Slip
dc.subject Pulses
dc.subject Inclusion
dc.subject Directivity
dc.subject Near-fault ground motions
dc.subject Model
dc.subject Fling-step
dc.subject Base-isolated buildings
dc.subject Pulse period
dc.subject Components
dc.subject Pgv
dc.subject Displacement spectra
dc.title Near-Fault Earthquake Ground Motion and Seismic Isolation Design
dc.type Conference Object
dspace.entity.type Publication
gdc.author.institutional Şadan, Bahadır
gdc.bip.impulseclass C5
gdc.bip.influenceclass C5
gdc.bip.popularityclass C5
gdc.coar.access metadata only access
gdc.coar.type text::conference output
gdc.description.department Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü
gdc.description.endpage 152
gdc.description.publicationcategory Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
gdc.description.scopusquality Q4
gdc.description.startpage 117
gdc.description.volume 309
gdc.description.woscitationindex Conference Proceedings Citation Index - Science
gdc.identifier.openalex W4313612995
gdc.identifier.wos WOS:000963575900009
gdc.index.type WoS
gdc.index.type Scopus
gdc.oaire.diamondjournal false
gdc.oaire.impulse 3.0
gdc.oaire.influence 2.7471405E-9
gdc.oaire.isgreen false
gdc.oaire.popularity 3.4809537E-9
gdc.oaire.publicfunded false
gdc.openalex.collaboration National
gdc.openalex.fwci 5.48585232
gdc.openalex.normalizedpercentile 0.93
gdc.openalex.toppercent TOP 10%
gdc.opencitations.count 2
gdc.plumx.mendeley 5
gdc.plumx.scopuscites 5
gdc.publishedmonth Ocak
gdc.relation.journal Seismic Isolation, Energy Dissipation and Active Vibration Control of Structures, 17wcsi 2022
gdc.relation.journal 17th World Conference on Base Seismic Isolation (WCSI) -- SEP 11-15, 2022 -- Dept Struct, Geotechn & Bldg Engn, Turin, ITALY
gdc.scopus.citedcount 6
gdc.virtual.author Şadan, Bahadır
gdc.wos.citedcount 4
gdc.wos.collaboration Uluslararası işbirliği ile yapılmayan - HAYIR
gdc.wos.documenttype Proceedings Paper
gdc.wos.indexdate 2023
gdc.wos.publishedmonth Ocak
gdc.yokperiod YÖK - 2022-23
relation.isAuthorOfPublication 5fa87f40-d4f3-443a-a4de-e40e4a2a5c97
relation.isAuthorOfPublication.latestForDiscovery 5fa87f40-d4f3-443a-a4de-e40e4a2a5c97
relation.isOrgUnitOfPublication c90327d7-cf5a-4775-a458-1dbb7ea10e32
relation.isOrgUnitOfPublication 0d54cd31-4133-46d5-b5cc-280b2c077ac3
relation.isOrgUnitOfPublication a6e60d5c-b0c7-474a-b49b-284dc710c078
relation.isOrgUnitOfPublication.latestForDiscovery c90327d7-cf5a-4775-a458-1dbb7ea10e32

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description: