dc.description.abstract The microwave imaging systems have the potential to present a cost effective and less hazardous alternative to conventional medical imaging techniques. In this paper, a Contrast Source Inversion method based microwave imaging scheme is proposed and tested for the detection of pulmonary edema and hemorrhage. To this end, a realistic human torso phantom is used, and the electromagnetic parameters of the human tissues is determined via Cole-Cole model. The scattered field is simulated via Method of Moments at the operating frequency of 350 MHz, and a 50 dB white Gaussian noise is added to model a realistic measurement setup. The numerical tests performed with the proposed technique suggest that the method can be used to locate the pulmonary edema and hemorrhage, and it is capable of distinguishing these two medical conditions successfully.
dc.identifier.citation Ertek, D., Kucuk, G., & Bilgin, E. (2022). A Microwave Imaging Scheme for Detection of Pulmonary Edema and Hemorrhage. 2022 30th Signal Processing and Communications Applications Conference (SIU). https://doi.org/10.1109/siu55565.2022.9864778
dc.identifier.doi 10.1109/SIU55565.2022.9864778
dc.identifier.isbn 9781665450928
dc.identifier.issn 2165-0608
dc.identifier.scopus 2-s2.0-85138721822
dc.identifier.uri https://hdl.handle.net/20.500.11779/1903
dc.language.iso tr
dc.publisher IEEE
dc.relation.ispartof 30th IEEE Signal Processing and Communications Applications Conference (SIU) -- MAY 15-18, 2022 -- Safranbolu, TURKEY
dc.relation.ispartofseries Signal Processing and Communications Applications Conference
dc.rights info:eu-repo/semantics/openAccess
dc.subject Contrast Source Inversion
dc.subject Microwave Imaging
dc.subject Pulmonary Edema
dc.subject Hemorrhage
dc.title A Microwave Imaging Scheme for Detection of Pulmonary Edema and Hemorrhage
dc.title.alternative Akcigerde Ödem ve Hemorajin Mikrodalga Görüntüleme ile Tespiti
dc.type Conference Object
dspace.entity.type Publication
gdc.author.id Bilgin, Egemen / 0000-0003-3517-6164
gdc.author.institutional Ertek, Didem, Küçük, Gökhan, Bilgin, Egemen
gdc.author.wosid Bilgin, Egemen/KJM-6362-2024
gdc.bip.impulseclass C5
gdc.bip.influenceclass C5
gdc.bip.popularityclass C5
gdc.coar.access open access
gdc.coar.type text::conference output
gdc.description.department Mühendislik Fakültesi, Elektrik Elektronik Mühendisliği
gdc.description.endpage 4
gdc.description.publicationcategory Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
gdc.description.scopusquality N/A
gdc.description.startpage 1
gdc.description.woscitationindex Conference Proceedings Citation Index - Science
gdc.description.wosquality N/A
gdc.identifier.openalex W4293863298
gdc.identifier.wos WOS:001307163400117
gdc.index.type WoS
gdc.index.type Scopus
gdc.oaire.diamondjournal false
gdc.oaire.impulse 1.0
gdc.oaire.influence 2.6115425E-9
gdc.oaire.isgreen true
gdc.oaire.keywords Contrast Source Inversion
gdc.oaire.keywords Hemorrhage
gdc.oaire.keywords Pulmonary Edema
gdc.oaire.keywords Microwave Imaging
gdc.oaire.popularity 3.1167948E-9
gdc.oaire.publicfunded false
gdc.openalex.collaboration International
gdc.openalex.fwci 1.11528105
gdc.openalex.normalizedpercentile 0.71
gdc.opencitations.count 1
gdc.plumx.scopuscites 1
gdc.publishedmonth Mayıs
gdc.relation.journal 2022 30th Signal Processing and Communications Applications Conference, Siu 2022
gdc.scopus.citedcount 1
gdc.virtual.author Bilgin, Egemen
gdc.wos.citedcount 0
gdc.wos.publishedmonth Mayıs
gdc.yokperiod YÖK - 2022-23
relation.isAuthorOfPublication f505a938-1bd6-41a7-a78b-872531404644
relation.isAuthorOfPublication.latestForDiscovery f505a938-1bd6-41a7-a78b-872531404644
relation.isOrgUnitOfPublication de19334f-6a5b-4f7b-9410-9433c48d1e5a
relation.isOrgUnitOfPublication 0d54cd31-4133-46d5-b5cc-280b2c077ac3
relation.isOrgUnitOfPublication a6e60d5c-b0c7-474a-b49b-284dc710c078
relation.isOrgUnitOfPublication.latestForDiscovery de19334f-6a5b-4f7b-9410-9433c48d1e5a

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A_Microwave_Imaging_Scheme_for_Detection_of_Pulmonary_Edema_and_Hemorrhage.pdf
Size:
2.4 MB
Format:
Adobe Portable Document Format
Description:
Full Text - Article

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description: