Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11779/1443
Title: Performance of High-Damping Rubber Bearings for Seismic Isolation of Residential Buildings in Turkey
Authors: Murota, N.
Tuzun, C.
Mori, T.
Şadan, Bahadır
Wakishima, K.
Suzuki, S.
Sutcu, F.
Erdik, M.
Keywords: High-damping rubber bearing
Turkish building seismic code
Residential buildingtime history analysis
Numerical modelprototype test
Full scale dynamic test
Seismic isolation
Publisher: Elsevier
Source: Murota, N., Suzuki, S., Mori, T., Wakishima, K., Sadan, B., Tuzun, C., Sutcu, F., ... Erdik, M. (April 01, 2021). Performance of high-damping rubber bearings for seismic isolation of residential buildings in Turkey. Soil Dynamics and Earthquake Engineering, 143.
Abstract: The applicability of high-damping rubber bearings for seismic isolation of residential buildings in Turkey is studied using numerical and experimental approaches. Seismic isolation system composed of high-damping rubber bearings is designed according to the recently updated Turkish Building Seismic Code-2018 (TBSC2018). Three model buildings of different height at assumed seismically active area are chosen from an actual building database, on which, equivalent lateral force procedure, and time history analyses are carried out. The seismic responses of the buildings are evaluated and the seismic isolation system's efficiency is confirmed. It is pointed out that the requirements in the new code in terms of the maximum allowable shear strain of elastomeric isolators are excessively conservative for those isolators with much larger capacity which is verified by sufficient test data, and as a result, designed isolator size becomes larger than necessary from a practical aspect. In order to verify the isolator design without compliance of shear strain limitation in the code, full-scale prototypes of high-damping rubber bearings are specially designed, developed and are subjected to dynamic loading test under test protocol specified in the code. The specific values of test conditions, such as compressive force, shear displacement and frequency, are developed referring several projects in Turkey. The results are comprehensively discussed and the applicability of high-damping rubber bearing for seismic isolation of residential buildings in Turkey is concluded with numerical and experimental approaches and a possible modification of TBSC2018 regarding maximum shear strain is proposed.
URI: https://hdl.handle.net/20.500.11779/1443
https://doi.org/10.1016/j.soildyn.2021.106620
Appears in Collections:İnşaat Mühendisliği Bölümü Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
1-s2.0-S0267726121000427-main.pdf
  Until 2040-01-01
Full Text - Article10.23 MBAdobe PDFView/Open    Request a copy
Show full item record



CORE Recommender

SCOPUSTM   
Citations

23
checked on Nov 23, 2024

WEB OF SCIENCETM
Citations

17
checked on Nov 23, 2024

Page view(s)

70
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.