Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11779/1580
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Genç, Garip | - |
dc.contributor.author | Şanlıtürk, Kenan Y. | - |
dc.contributor.author | Saygılı, Yusuf | - |
dc.contributor.author | Körük, Hasan | - |
dc.date.accessioned | 2021-10-26T10:58:44Z | |
dc.date.available | 2021-10-26T10:58:44Z | |
dc.date.issued | 2021 | - |
dc.identifier.citation | Koruk, H., Saygili, Y., Genc, G., & Sanliturk, K. Y. (1 September 2021). Identification of uncertainty levels of acoustic properties of biocomposites under different mounting conditions in impedance tube tests. Noise Control Engineering Journal, 69(5), 392–400. https://doi.org/10.3397/1/376936 | en_US |
dc.identifier.issn | 0736-2501 | - |
dc.identifier.uri | https://hdl.handle.net/20.500.11779/1580 | - |
dc.identifier.uri | https://doi.org/10.3397/1/376936 | - |
dc.description.abstract | Impedance tube method is widely used to measure acoustic properties of materials. Although this method yields reliable acoustic properties for soft textured materials, uncertainty levels of measured acoustic properties for hard materials, including biocomposites, can be quite large, mainly due to uncertain mounting conditions. Here, the effects of mounting conditions on the acoustic properties of biocomposites in an impedance tube are investigated. First, nominally identical biocomposite samples with a diameter equal to the inner diameter of impedance tube are manufactured and their acoustic properties are determined. As hard materials practically cause fitting problems in the impedance tube, the diameters of samples are reduced, as in practice, by small amounts and acoustic properties of modified samples are determined. Furthermore, in order to match the diameters of samples to the inner diameter of impedance tube, different materials such as tape, petroleum jelly and cotton are applied around samples to close the air gap between the samples and the tube's inner wall. All the results are compared, and the uncertainty levels caused by different mounting conditions on the acoustic properties of biocomposites are identified. The results show that the transmission loss (TL) measurements are dramatically affected by the mounting conditions while the sound absorption conditions are less sensitive to the mounting conditions. The deviations in the measured TL levels are highest for the samples with tape and wax (10–15 dB). On the other hand, the deviations in the measured sound absorption coefficients are highest for the samples with cotton and tape (1–2%). | en_US |
dc.language.iso | en | en_US |
dc.publisher | Institute of Noise Control Engineering | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Acoustic Properties | en_US |
dc.subject | Air Gap | en_US |
dc.subject | Inner Diameter | en_US |
dc.subject | Absorption Coefficients | en_US |
dc.subject | Petroleum Jelly | en_US |
dc.subject | Other Hand | en_US |
dc.subject | Properties Of Materials | en_US |
dc.subject | Sound Absorption | en_US |
dc.subject | Hard Materials | en_US |
dc.subject | Impedance Tube | en_US |
dc.title | Identification of Uncertainty Levels of Acoustic Properties of Biocomposites Under Different Mounting Conditions in Impedance Tube Tests | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.3397/1/376936 | - |
dc.identifier.scopus | 2-s2.0-85119483800 | en_US |
dc.authorid | Hasan Körük / 0000-0003-4189-6678 | - |
dc.description.woscitationindex | Science Citation Index Expanded | - |
dc.identifier.wosquality | Q4 | - |
dc.description.WoSDocumentType | Article | |
dc.description.WoSInternationalCollaboration | Uluslararası işbirliği ile yapılmayan - HAYIR | en_US |
dc.description.WoSPublishedMonth | Eylül | en_US |
dc.description.WoSIndexDate | 2020 | en_US |
dc.description.WoSYOKperiod | YÖK - 2020-21 | en_US |
dc.identifier.scopusquality | Q4 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.startpage | 392-400 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.volume | 69 | en_US |
dc.department | Mühendislik Fakültesi, Makine Mühendisliği Bölümü | en_US |
dc.relation.journal | Noise Control Engineering Journal | en_US |
dc.identifier.wos | WOS:000708228600001 | en_US |
dc.institutionauthor | Körük, Hasan | - |
item.fulltext | With Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.languageiso639-1 | en | - |
item.openairetype | Article | - |
item.grantfulltext | open | - |
item.cerifentitytype | Publications | - |
Appears in Collections: | Makine Mühendisliği Bölümü Koleksiyonu Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
KorukEtAl2021ImpedanceTube.pdf | Full Text - Article | 2.99 MB | Adobe PDF | View/Open |
CORE Recommender
SCOPUSTM
Citations
3
checked on Nov 9, 2024
Page view(s)
26
checked on Nov 4, 2024
Download(s)
12
checked on Nov 4, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.