Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11779/211
Title: The Effects of Ultrasound Parameters and Microbubble Concentration on Acoustic Particle Palpation
Authors: Körük, Hasan
Saharkhiz, Niloufar
Choi, James J
Publisher: Acoustical Society of America
Source: Saharkhiz, N., Koruk, H,. Choi, J.J. ( August 17, 2018 ) The Effects of Ultrasound Parameters and Microbubble Concentration on Acoustic Particle Palpation, The Journal of the Acoustical Society of America 144(2), pp.796-805. https://doi.org/10.1121/1.5050524
Abstract: The elasticity of tissue—an indicator of disease progression—can be imaged by ultrasound elasticity imaging technologies. An acoustic particle palpation (APP) has recently been developed—the use of ultrasonically driven acoustic particles (e.g., microbubbles)—as an alternative method of tissue deformation. APP has the potential to improve the resolution, contrast, and depth of ultrasound elasticity imaging; but the tissue displacement dynamics and its dependence on acoustic pressure, center frequency, and microbubble concentration remains unknown. Here, displacements of at least 1 μm were produced by applying ultrasound onto a microbubble solution (concentration: 10 × 106 microbubbles ml–1) placed within a tunnel surrounded by a 5% gelatin phantom. Displacements of more than 10 μm were produced using a 1, 3.5, or 5 MHz center frequency pulse with peak-rarefactional pressures of 470, 785, and 1210 kPa, respectively. The deformation of the distal wall varied spatially and temporally according to the different parameters investigated. At low pressures, the deformation increased over several milliseconds until it was held at a nearly constant value. At high pressures, a large deformation occurred within a millisecond followed by a sharp decrease and long stabilization. Ultrasound exposure in the presence of microbubbles produced tissue deformation (p < 0.05) while without microbubbles, no deformation was observed.
URI: https://hdl.handle.net/20.500.11779/211
ISSN: 0001-4966
Appears in Collections:Makine Mühendisliği Bölümü Koleksiyonu
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
Sharkhiz_Koruk_Choi2018.pdfYazar Sürümü1.86 MBAdobe PDFThumbnail
View/Open
The effects of ultrasound parameters and microbubble concentration on acoustic.pdf
  Until 2093-08-17
Yayıncı Sürümü3.41 MBAdobe PDFView/Open    Request a copy
Show full item record



CORE Recommender

SCOPUSTM   
Citations

7
checked on Nov 16, 2024

WEB OF SCIENCETM
Citations

6
checked on Nov 16, 2024

Page view(s)

20
checked on Nov 18, 2024

Download(s)

10
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.