Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/20.500.11779/1926
Browse
Browsing Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection by browse.metadata.publisher "Acoustical Society of America"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Article Citation - WoS: 7Citation - Scopus: 9Displacement of a Bubble Located at a Fluid-Viscoelastic Medium Interface(Acoustical Society of America, 2019) Körük, Hasan; Choi, James J.A model for estimating the displacement of a bubble located at a fluid-viscoelastic medium interface in response to acoustic radiation force is presented by extending the model for a spherical object embed- ded in a bulk material. The effects of the stiffness and viscosity of the viscoelastic medium and the amplitude and duration of the excitation force on bubble displacement were investigated using the proposed model. The results show that bubble displacement has a nonlinear rela- tionship with excitation duration and viscosity. The time at which the steady state is reached increases with increasing medium viscosity and decreasing medium stiffness.Article Citation - WoS: 6Citation - Scopus: 7The Effects of Ultrasound Parameters and Microbubble Concentration on Acoustic Particle Palpation(Acoustical Society of America, 2018) Körük, Hasan; Saharkhiz, Niloufar; Choi, James JThe elasticity of tissue—an indicator of disease progression—can be imaged by ultrasound elasticity imaging technologies. An acoustic particle palpation (APP) has recently been developed—the use of ultrasonically driven acoustic particles (e.g., microbubbles)—as an alternative method of tissue deformation. APP has the potential to improve the resolution, contrast, and depth of ultrasound elasticity imaging; but the tissue displacement dynamics and its dependence on acoustic pressure, center frequency, and microbubble concentration remains unknown. Here, displacements of at least 1 μm were produced by applying ultrasound onto a microbubble solution (concentration: 10 × 106 microbubbles ml–1) placed within a tunnel surrounded by a 5% gelatin phantom. Displacements of more than 10 μm were produced using a 1, 3.5, or 5 MHz center frequency pulse with peak-rarefactional pressures of 470, 785, and 1210 kPa, respectively. The deformation of the distal wall varied spatially and temporally according to the different parameters investigated. At low pressures, the deformation increased over several milliseconds until it was held at a nearly constant value. At high pressures, a large deformation occurred within a millisecond followed by a sharp decrease and long stabilization. Ultrasound exposure in the presence of microbubbles produced tissue deformation (p < 0.05) while without microbubbles, no deformation was observed.