The Effects of Ultrasound Parameters and Microbubble Concentration on Acoustic Particle Palpation

Loading...
Thumbnail Image

Date

2018

Journal Title

Journal ISSN

Volume Title

Publisher

Acoustical Society of America

Open Access Color

HYBRID

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Average
Popularity
Top 10%

Research Projects

Journal Issue

Abstract

The elasticity of tissue—an indicator of disease progression—can be imaged by ultrasound elasticity imaging technologies. An acoustic particle palpation (APP) has recently been developed—the use of ultrasonically driven acoustic particles (e.g., microbubbles)—as an alternative method of tissue deformation. APP has the potential to improve the resolution, contrast, and depth of ultrasound elasticity imaging; but the tissue displacement dynamics and its dependence on acoustic pressure, center frequency, and microbubble concentration remains unknown. Here, displacements of at least 1 μm were produced by applying ultrasound onto a microbubble solution (concentration: 10 × 106 microbubbles ml–1) placed within a tunnel surrounded by a 5% gelatin phantom. Displacements of more than 10 μm were produced using a 1, 3.5, or 5 MHz center frequency pulse with peak-rarefactional pressures of 470, 785, and 1210 kPa, respectively. The deformation of the distal wall varied spatially and temporally according to the different parameters investigated. At low pressures, the deformation increased over several milliseconds until it was held at a nearly constant value. At high pressures, a large deformation occurred within a millisecond followed by a sharp decrease and long stabilization. Ultrasound exposure in the presence of microbubbles produced tissue deformation (p < 0.05) while without microbubbles, no deformation was observed.

Description

Keywords

570, MD Multidisciplinary, 610, Acoustics

Turkish CoHE Thesis Center URL

Fields of Science

0103 physical sciences, 01 natural sciences

Citation

Saharkhiz, N., Koruk, H,. Choi, J.J. ( August 17, 2018 ) The Effects of Ultrasound Parameters and Microbubble Concentration on Acoustic Particle Palpation, The Journal of the Acoustical Society of America 144(2), pp.796-805. https://doi.org/10.1121/1.5050524

WoS Q

Q1

Scopus Q

Q1
OpenCitations Logo
OpenCitations Citation Count
7

Source

The Journal of the Acoustical Society of America

Volume

144

Issue

2

Start Page

796

End Page

805
PlumX Metrics
Citations

CrossRef : 6

Scopus : 7

Captures

Mendeley Readers : 14

SCOPUS™ Citations

7

checked on Feb 03, 2026

Web of Science™ Citations

6

checked on Feb 03, 2026

Page Views

207

checked on Feb 03, 2026

Downloads

1079

checked on Feb 03, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.48558979
Altmetrics Badge

Sustainable Development Goals

SDG data is not available