İnşaat Mühendisliği Bölümü Koleksiyonu

Permanent URI for this collectionhttps://hdl.handle.net/20.500.11779/1943

Browse

Search Results

Now showing 1 - 5 of 5
  • Conference Object
    Seismic Performance of Damaged Code-Conforming Rc Columns Repaired With Sustainable Structural Mortar
    (Elsevier B.V., 2024) Kolemenoglu, S.; Halici, O.F.; Demir, C.; Aydemir, C.; Aydemir, M.E.; Ilki, A.
    Examining the seismic performance of damaged reinforced concrete (RC) structures after repair applications is vital for an effective post-earthquake disaster management policy. However, the number of experimental studies investigating the seismic behavior of repaired RC members is insufficient, especially for structural members that have endured slight or moderate level damages. In this study, four identical large-scale code-conforming RC columns were tested under combined effects of axial load and reversed cyclic lateral displacements. The reference column was tested until failure, while the remaining three columns were first imposed to lateral displacements until the formation of damages at different levels, then repaired with structural repair mortar that contains recycled raw materials without removing axial load and tested again until failure. The primary objectives of the experimental program are to enhance the knowledge on the post-earthquake performance of damaged RC columns and to investigate the effects of repair applications after slight and moderate damage levels. This paper provides details on the effectiveness of the aforementioned repair technique on the seismic performance of code-complying RC columns damaged at different damage levels. © 2024 Elsevier B.V.. All rights reserved.
  • Conference Object
    Citation - WoS: 2
    Citation - Scopus: 3
    An Overview on the Structural Monitoring, Assessment and Retrofitting of Historical Structures With a Focus on 13th Century Monuments
    (Springer international Publishing Ag, 2024) Ilki, Alper; Inci, Pinar; Halici, Omer F.; Demir, Cem; Comert, Mustafa; Kuran, Fikret
    Monumental historical structures affirm natural and cultural identity and hence they should be transmitted to future generations. The protection and preservation of these structures against aging and natural hazards, particularly seismic actions, requires a comprehensive approach including diagnosis of the present condition of the structure and enhancement of structural capacity for disaster mitigation, if necessary. It is obvious that due to their historical values, any attempt towards the preservation of the monumental historical structures must be carried out with respect to the principles of integrity and authenticity. In this study, the structural performance assessment procedures, implementation of structural health monitoring systems and seismic strengthening strategies are discussed and described with reference to 13th-century monumental historical structures in Turkiye. The structural engineering aspects of recent activities for the restoration and preservation of the Great Mosque and Hospital of Divrigi (a world heritage listed structure) and Sivas Ulu Cami (Mosque) Minaret are briefly presented. In light of the structural analysis and monitoring results, recommendations for interventions to these monumental structures are outlined.
  • Conference Object
    Numerical Seismic Performance Investigation of Aac Infill Walls With Flat-Truss Bed-Joint Reinforcement
    (National Technical University of Athens, 2023) İlki, Alper; Halıcı, Ömer Faruk
    Autoclaved Aerated Concrete (AAC) is a lightweight, energy-efficient and easy-to-transport material. As a result, AAC walls are becoming increasingly common as an infill solution in earthquake-prone areas such as Turkey, Italy, and Greece. Although infills are considered as secondary components in seismic design, they are extremely vulnerable to damage during earthquakes along both in-plane (IP) and out-of-plane (OOP) directions. Previous post-earthquake site examinations revealed that the failure of infill walls can result in serious injuries and casualties. Furthermore, huge economic losses as well as disruption in the functionality of essential buildings that are supposed to be operational after earthquakes may adversely affect the daily life in the earthquake-affected regions. One of the potential methods for increasing the seismic resilience of infill walls is use of bed-joint reinforcement between infill courses. In this paper, the general approaches in the establishment of the numerical finite element model for infill walls with and without bed-joint reinforcement are presented. The developed model was evaluated according to the previous full-scale experimental test results from strength and damage propagation point of view. The model will be used to investigate the response of infills with various bed-joint reinforcement amounts and height-to-length ratios to generalize the seismic performance improvements obtained by the use of flat-truss reinforcement both in the IP and OOP directions.
  • Conference Object
    Citation - WoS: 7
    Citation - Scopus: 5
    State of the Art in Application of Seismic Isolation and Energy Dissipation in Turkey
    (Springer International Publishing Ag, 2023) Şadan, Bahadır
    This paper summarizes the passive structural control system applications and other related developments in Turkey, emphasizing the period between 2019 and 2022. The country hosts state-of-the-art seismic isolation applications, relatively greater in size, and use more isolators in each project (415 isolators per building on average) compared to the other seismic isolation projects worldwide. Construction of the world's largest seismic isolated building, Istanbul Basaksehir Pine and Sakura City Hospital, covering more than 1 million square meters of area and employing more than 2000 seismic isolators, was completed and has been in service since May 2020. 1915 Canakkale Bridge, constructed in memory of the great war of Canakkale during World War I, is now the world's longest suspension bridge with a 2023m main span length. Eight massive hydraulic dampers were used at the main deck and 48 at the approach viaducts in combination with 72 seismic isolators. Construction of a residential building complex in Istanbul consisting of 16 isolated blocks covering more than 170,000 m(2) area and having 454 seismic isolators is coming to an end very soon. Historical Nusretiye Clock Tower in Istanbul was relocated a few meters over seismic isolators. Historical Goztepe Railway Station in Istanbul was retrofitted to accommodate an additional railway line using seismic isolation technology. Seismic codes for buildings and bridges now include rules for the seismically isolated design of structures. Additionally, all seismic isolation designs must be peer-reviewed by law. A new seismic isolator testing facility was established in Eskisehir to respond to the demand for the large number of isolators that need to be tested.
  • Conference Object
    Citation - WoS: 6
    Citation - Scopus: 11
    Near-Fault Earthquake Ground Motion and Seismic Isolation Design
    (Springer International Publishing Ag, 2023) Harmandar, Ebru; Erdik, Mustafa; Demircioglu-Tumsa, Mine B.; Şadan, Bahadır; Tuzun, Cuneyt; Ulker, Omer
    Seismic isolation is one of the most reliable passive structural control techniques with adequately established standards for the earthquake protection of structures from earthquakes. However, it has been shown that the seismic isolation systems may not function the best for the near-fault ground motions, since in the proximity of a capable fault, the ground motions are significantly affected by the rupture mechanism and may generate high demands on the isolation system and the structure. In fact, several earthquake resistant design codes state that the seismically isolated structures located at near-fault sites should be designed by considering larger seismic demands than the demand on structures at far-field sites. When the fault ruptures in forward direction to the site most of the seismic energy arrives in coherent long-period ground velocity pulses. The ground-motion prediction equations (GMPEs) typically cannot account for such effects with limited distance metrics and lack adequate data at large magnitudes and near distances. For the reliable earthquake design of the isolated structure in near fault conditions that meets the performance objectives, the 3D design basis ground motion(s) need to be appropriately assessed. Measures in the design of the isolation system, such as modifications in the stiffness and damping characteristics, as well as in the limitation of vertical effects are needed. The behavior of the base-isolated buildings under near-fault (NF) ground motions with fling-step and forward-directivity characteristics are investigated with a rational assessment of design-basis near-fault ground motion, are investigated in a parametric format. The parametric study includes several variables, including the structural system flexibility; number of stories; isolation system characteristic (yield) strength, and the isolation periods related to the post-elastic stiffness. Furthermore, the effect of additional damping by viscous dampers were tested for some selected cases. Important findings observed from the parametric performance results and the overall conclusions of the study are provided.